How to Choose a Charging Station for Your Home Office: Battery, Solar, and USB Power Compared

Most people who search for a home office charging station are picturing a plastic block with six USB ports. That object exists, and it does its job — but it cannot do the thing that usually prompts the search: keep the work going when the mains stops. This guide is about the other category, the battery-powered charging station that the industry calls a portable power station: a unit you charge from the wall or from a solar panel, then run laptops, monitors, routers and phones from during an outage or a working day away from a socket.

The naming matters, because three different products are sold with overlapping language. A multi-port USB charger splits one wall adapter's output across its ports. A power strip multiplies sockets on the same ring main. A portable power station stores energy in a battery and releases it through its own inverter. And if what you actually need is to charge a vehicle, that is a different job with different regulations and a licensed installer — the EV charging station for home guide covers that separately.

So the decision in front of you has three variables, and realistically only three: how much energy your desk actually consumes in a working day, whether you need stored energy at all or simply tidier charging, and how much floor space, weight and fan noise you are prepared to live with. Port counts, app features and built-in lights are secondary unless they solve one of those three.

How to Choose a Charging Station for Your Home Office: Battery, Solar, and USB Power Compared

Why a Dedicated Charging Station Beats a Power Strip for Home Offices

A power strip and a battery-backed station solve different problems, and conflating them is the most common reason people spend money and still feel unprotected.

A power strip gives you more sockets on the same circuit. When that circuit goes down — tripped RCD, planned works, a wider outage — every socket goes down with it. It also concentrates your entire desk onto one point of failure, and it does nothing about the fact that a laptop, a monitor, a router, a VoIP handset and two phones each want a different voltage and a different negotiation protocol.

A battery-powered charging station changes the failure domain. Your devices draw from a battery through an inverter, and the wall becomes a recharge path rather than a dependency. That is the entire value proposition, and it is worth being blunt about the cost of it: stored energy is expensive per unit, it ages, it takes up space and it weighs something. If your area has never lost power for more than a few minutes, a good 100W USB-C charger and a cable tray will serve you better for a fraction of the money.

There is a middle case that catches a lot of freelancers. A USB-only hub is genuinely the right answer for tidiness — one adapter, one cable to the desk, no wall-wart farm — but only if you accept that it protects nothing. The moment you add a battery, you are buying insurance as well as organisation, and the sizing rules change completely.

The Four Criteria That Actually Decide This

Ignore marketing watts. Four numbers do most of the work.

1. Usable watt-hours per working day. Not nameplate capacity. A battery's usable energy is lower than its label, and the inverter loses a slice of whatever passes through it. Practical rule: take the rated capacity, knock off roughly 15%, and divide by your desk's continuous load in watts. That gives you hours, and hours is the number you actually care about.

2. Continuous AC watts, and the surge behind it. Continuous rating decides what runs; surge rating decides what starts. A laser printer, a fan or a small fridge pulls a brief multiple of its running load at start-up, which is what the surge figure covers. If the continuous figure is below your combined load, the station trips — surge ratings will not save you.

3. Laptop-capable ports, not port count. This is where most buying decisions go wrong, and it gets its own section below because it deserves one.

4. Physical and acoustic footprint. A 22kg unit is a floor object, not a desk object. A unit with a published noise figure under 30dB is effectively silent from a metre away; one rated nearer 50dB is audible in a quiet room and noticeable on a call.

If you want a fifth criterion, make it the recharge path: how quickly the station refills from the wall, and whether it can take solar at all. Capacity without a fast refill just means a longer wait between outages.

Battery-Powered vs. Solar vs. USB-Only: Which Power Method Fits Your Workday?

Three approaches, three trade-offs.

USB-only (no battery). Cheapest, smallest, silent, zero maintenance. A four-port USB charging station with a universal socket will tidy a desk beautifully and split something like 100W across its ports, which is plenty for phones, tablets and a thin laptop. What it will not do is survive an outage, and it cannot exceed the wall adapter's total budget no matter how many ports it advertises.

Battery-powered, mains-recharged. The default for home offices. You get hours of outage cover, you can move the unit between rooms, and nothing needs installing. The trade-off is chemistry and weight. LiFePO4 packs dominate this segment for good reason — typical cycle life runs in the region of 2,000 to 3,500+ cycles, against roughly 500 to 1,000+ for NMC/NCA designs — but they are heavier per watt-hour. If you plan to carry the unit to a campsite as well as keep it under a desk, that weight is a real constraint.

Solar-assisted. A battery station plus a folding panel. This is the only approach that scales through a multi-day outage without a generator, and it is also the one most often oversold. Expect roughly 60% to 80% of a panel's nameplate rating in good sun, and less with heat, haze, a poor angle or a window in the way. Solar also adds a second purchase, a second storage problem and a placement problem. It earns its place when outages routinely run past a single working day, or when the workspace itself has no mains at all.

Approach Outage cover Cost per useful hour Space and noise Choose when
USB-only hub None Lowest Minimal, silent Outages are rare and short; the goal is cable tidiness
Battery station, mains recharge 4–18 hours depending on capacity Moderate One box, 6–22kg You need to finish the working day through a cut
Battery station + folding solar Indefinite with good weather and enough panel Highest up front Extra 7kg panel plus outdoor placement Outages exceed a day, or the workspace is off-grid

Sizing Your Station: How to Calculate Watt-Hours for Your Devices

Do this on paper before you look at any product page, because it converts a confusing market into a single number.

Start with the honest draw of each device, not the rating printed on its charger. A charger's wattage is a ceiling; a 65W USB-C laptop adapter typically supplies somewhere around 45W during ordinary document and browser work. If you want real figures rather than estimates, borrow or buy a plug-in energy meter and leave it on the desk circuit for a week — that single measurement removes most of the guesswork.

Then multiply by hours and add a margin. Here is a realistic single-person setup, with a desktop monitor and a VoIP line:

Device Realistic draw Hours per day Watt-hours
Laptop (65W USB-C adapter, working load) 45W 8 360Wh
24-inch monitor 25W 8 200Wh
Mesh router and fibre termination box 12W 8 96Wh
VoIP desk phone 5W 8 40Wh
Phone 10W 4 40Wh
LED desk lamp 8W 5 40Wh
Daily total ≈97W continuous — 776Wh
Plus 18% conversion margin — — ≈916Wh

That number does something useful: it eliminates whole categories. A 512Wh unit cannot cover this desk for a full day. A 1024Wh unit can, with about 9 hours of headroom once conversion losses are allowed for. A 2048Wh unit covers nearly two working days.

Now strip the monitor and the lamp out. Laptop, router and phone come to 67W continuous, or about 79W with margin applied — and a 512Wh station will carry that for roughly six and a half hours. That is the realistic use case for the smallest tier: the stripped-down essentials for most of a day, not the whole desk for all of it.

One product illustration of that tier: the OUKITEL P800 pairs a 512Wh LiFePO4 pack with an 800W pure sine wave inverter and a 1600W surge rating, weighs 6kg and measures 29.4 × 17.8 × 20.5cm. Charging from the wall at 500W brings it to full in about an hour, which is the spec that matters after an outage — you are not waiting overnight to be protected again. Its 200W solar ceiling and 2.75-hour solar recharge time are modest, but consistent with a unit this size.

The 12V/USB Port Trap: Why Port Count Doesn't Guarantee Laptop Charging

Two stations can both advertise eight outputs and behave completely differently, because ports negotiate at different wattages. Count the ports that can run a laptop at its rated speed, and ignore the rest.

The clearest example sits inside a single product line. The P800 lists six USB and DC outputs, but only one of them is a USB-C PD 100W port. The second USB-C is a QC3 18W port and the USB-A ports are 12W. Run a 65W laptop from an 18W port and it will discharge under load, not charge. The same pattern repeats up the range: the OUKITEL P1000 PLUS pairs one USB-C PD 100W port with a PD 20W port and two 18W USB-A ports; the OUKITEL P2001 Plus has four USB-C ports, of which one is 100W, one is 45W and two are 20W.

There is a second layer to this. USB Power Delivery now runs in Extended Power Range, up to 240W over USB-C at 48V and 5A, and EPR charging requires a 5A e-marked USB-C cable as well as a port that explicitly supports EPR. The highest USB-C output across the three stations above is 100W, which comfortably covers ultrabooks and most 13–14 inch business laptops, but not a 140W or 240W workstation laptop. If you own one of those, plan to run it from the AC outlet with its own adapter rather than assuming the USB-C port will keep pace.

The 12V side has its own arithmetic. A car accessory socket is commonly fused at 10A to 15A, which puts practical output around 120W to 180W at 12V, and portable stations tend to mirror that format. The P800 provides two 12V DC outputs plus a car outlet, which is genuinely useful if your kit includes a 12V router, a monitor or a radio. The P1000 PLUS and P2001 Plus list no 12V DC outputs in their specifications — so if a 12V USB charging station function is on your must-have list, check that carefully before buying.

A negative example worth learning from. Suppose a freelance designer buys on port count: a station with eight outputs, of which exactly one delivers laptop-class power. During a two-hour outage they plug the laptop into a 20W USB-C port, the monitor into another, and discover that the laptop is losing charge while they work. They move the laptop to the single 100W port and put the monitor on AC — and now the inverter load roughly doubles. The station was never the problem; the port audit was skipped.

Solar Charging for Home Offices: When It Makes Sense and How to Size Panels

Solar is the only way to convert a one-day battery into an open-ended one, and it is also the most frequently mis-sized purchase in this category.

The sizing rule that works: take your daily watt-hour figure, divide by the number of usable peak-sun hours in your location on the worst month you care about, then divide again by about 0.7 to account for real-world harvest. For the 916Wh desk above, with four peak-sun hours, that lands at roughly 327W of nameplate panel. A single 200W panel will return somewhere near 560Wh on a good day — about 60% of a working day, not all of it. Two panels get you to roughly 1,120Wh and genuine energy independence in summer.

Solar only makes sense if you have an unshaded outdoor position: a balcony, a garden, a south-facing sill wide enough for a folded panel. Panels behind glass lose meaningful output, panels at a shallow angle lose more, and panels left in direct sun on a hot day lose output to heat as well. If your only option is a north-facing window in a rented flat, skip solar and buy a bigger battery instead.

The panel itself matters less than the pairing. The OUKITEL 200W Portable Solar Panel is a monocrystalline ETFE-laminated folding panel rated at 200W with a stated 24.8% cell efficiency, IP68 splash resistance and a 7kg carry weight, folding to 576.5 × 606 × 60mm. Its electrical figures are the ones to match against your station: 25V open-circuit, 18V at maximum power, 11.1A maximum power current, MC4 connectors and a 3m cable. It is quoted as compatible with the P2001 Plus and P1000 Plus at up to two panels each, and with the larger off-grid units at up to five. Its own certifications are listed as FCC, CE and RoHS, with a 12-month warranty and a working range of -10°C to 65°C, best at 25°C.

One practical warning: the P800 does not appear on that published compatibility list. Its solar input is capped at 200W, so a single 200W panel is arithmetically in range, but connector and voltage compatibility should be confirmed with the manufacturer before you buy the pair. This is exactly the kind of check that separates a working solar setup from an expensive folding object in a cupboard.

Also be realistic about recharge times with real panels rather than rated ones. The P1000 PLUS quotes a 2.05-hour solar recharge, but that is at its full 500W input. Feed it two 200W panels delivering perhaps 280W in real conditions and you are nearer four hours. The P2001 Plus, quoted at 80% in 2.75 hours from 500W of solar, is closer to six hours on the same two panels. Neither is a problem — but if you were counting on a lunchtime refill, it changes the plan.

Placement, Noise, and Cable Management: Practical Constraints for Small Offices

This is where specifications stop being abstract. The P800 at 6kg and 29.4 × 17.8 × 20.5cm can live on a deep windowsill or beside a desk leg without being in the way. The P1000 PLUS at 12kg and 34.6 × 22.8 × 23.8cm wants a shelf or the floor under the desk. The P2001 Plus at 22kg and 39.9 × 28.6 × 32cm is a floor unit and should be treated as semi-permanent — you will not be moving it between rooms casually.

Noise separates the tiers more than the marketing suggests. The P1000 PLUS is quoted at under 29dB, which in a quiet room is effectively inaudible and will not register on a call. The P2001 Plus is quoted at under 50dB, which is audible — comparable to a quiet conversation — and worth planning around if you record audio at your desk. The P800 does not publish a noise figure in its specifications, so if silence is critical, ask before assuming.

Temperature is the constraint people forget. All three units are rated for operation between 0°C and 40°C, with storage between -10°C and 40°C. That rules out an unheated garden office in February, a loft in a heatwave and a conservatory in July. It also means you should not box the unit in — inverters and batteries need airflow, and a station wedged behind a drawer unit will run warmer and louder than one with clearance.

For cable management, the useful discipline is to separate the AC side from the DC side. Put the station on the floor, run a single 100W USB-C cable up to the desk for the laptop, and let the phones charge on a small hub at desk level. That arrangement replaces three or four wall adapters with one cable, which was probably half the reason you started looking at a portable power charging station in the first place.

Regulations and Safety: What the Certifications Actually Tell You

Battery products in a home office sit at the intersection of three regulatory systems, and the labels on the box rarely explain which is which.

Product safety. In the US, UL 2743 is the current UL standard covering portable and movable power packs built around one or more battery or electrochemical capacitor modules — the category these stations sit in. What a listing tells you is that a specific configuration was evaluated; what it does not tell you is that every model under a brand name shares that evaluation. Ask for the model-specific documentation, not a brand-level statement.

Transport. UN38.3 is the lithium battery transport test regime, and it is the reason a courier or airline will accept the unit at all. It says nothing about how safe the product is in your office, but it does matter if you plan to ship the station or fly with it, since airlines apply their own watt-hour caps on top.

Market access and materials. FCC covers radio and emissions for the US market, CE marks EU conformity, and RoHS restricts hazardous substances. These are common frameworks for consumer sale, but whether each applies depends on the specific product configuration and the market you are buying in — a CE mark on a European listing is expected, while a US-facing model may carry a different set. The 200W panel above, for instance, lists FCC, CE and RoHS; the stations' published specification sheets in this range do not list certifications at all, which is a question to put to the seller rather than an assumption to make.

Charging protocols. USB Power Delivery compliance is administered through the USB-IF, whose current compliance materials still cover both Standard Power Range and Extended Power Range. A port that does not conform may still charge a phone, but it may not negotiate the voltage a laptop expects.

Backup claims. A transfer time is a specification, not a guarantee. The P800 and P1000 PLUS both state EPS switchover below 10ms; the P2001 Plus specification sheet does not quote a transfer time, so do not assume one. Even where a figure is quoted, whether your desktop survives a cut depends on the hold-up time of its own power supply. Consumer UPS units are designed for near-instant transfer, while battery stations in EPS mode vary by model, and a desktop that reboots on a 20ms gap will reboot regardless of what the box claims.

Fixed installation rules. A portable station is not a fixed installation. It cannot be wired into a ring main, it has no feed-in capability, and daisy-chaining it behind an extension lead with a heater on the same strip is how people create problems. If your workspaces are rented, check your contents insurance for how battery storage is treated before you site a 2kWh pack in a spare room.

Common Mistakes to Avoid When Choosing a Home Office Charging Station

The failure modes here are predictable enough to list.

  • Buying on watt-hour headline alone. A 1024Wh pack with a 300W inverter cannot run a desktop workstation, and the capacity figure will not warn you.
  • Assuming all USB-C ports are equal. Covered above, and still the single most common source of disappointment.
  • Sizing for a week instead of a day. Most outages last hours. Buying for a week of autonomy means paying for capacity that ages unused — and LiFePO4 ages whether you cycle it or not.
  • Forgetting the refill. A station that takes eight hours to recharge from the wall is a one-shot resource during a day of rolling cuts. Check the AC input wattage, not just the capacity.
  • Placing it outside its temperature window. 0°C to 40°C operating is a narrow band in a British or northern European winter. A cold garage is out.
  • Budgeting for the panel but not the position. Solar needs an unshaded, correctly angled outdoor spot. If you do not have one, the panel is dead weight.
  • Confusing charging station with vehicle charger. A home office power station cannot charge an electric car, and the fixed wall unit that can requires its own circuit, earthing and notification steps.

Portable Power Station vs. UPS vs. USB Hub: Which One Fits Your Setup?

These three products are often shopped for interchangeably and they are not interchangeable.

USB hub / charger UPS Portable power station
What it protects Nothing Connected devices, continuously Whatever you plug into it
Runtime Not applicable Minutes, sized for shutdown Hours, sized for work
Mobility Desk-bound Fixed to the mains Portable
Typical noise None Low, with alarms Silent to audible depending on model
Best for Everyday tidiness Protecting a desktop from short cuts Continuing to work through an outage

A practical combination many home offices land on: a small UPS on the desktop tower or the NAS, where a reboot costs data, plus a portable station for the laptop, router and phones, where the requirement is simply to keep working. That split also means the station's transfer time stops being a critical specification.

If you only buy one thing and you run a desktop, buy the UPS. If you run a laptop and want to keep working through a cut, buy the station.

Scenario and Budget Matrix: Light, Medium and Heavy Use

Budget tiers here are defined by capacity class rather than by price, because prices move and specifications do not. Once you have shortlisted within a tier, compare cost per watt-hour across the shortlist — the figure falls noticeably as capacity rises, so a larger unit is often better value per stored hour even though it costs more overall.

Profile Typical load Daily energy Capacity class Budget tier Priorities
Light — laptop, router, phone, no monitor ≈67W ≈540Wh 500Wh class Entry One PD 100W port, low weight, fast AC recharge
Medium — laptop, monitor, router, VoIP, lamp ≈97W ≈780Wh 1,000Wh class Mid Continuous AC headroom, published noise figure, app monitoring
Heavy — desktop workstation or two people sharing ≈230W ≈1,840Wh 2,000Wh class High Surge rating, floor placement, transfer time, solar input

For the middle band, the OUKITEL P1000 PLUS maps closely to the criteria: 1,024Wh of LiFePO4 with a stated 4,000-cycle life, an 1,800W pure sine wave inverter with 3,600W surge, four AC outlets, one USB-C PD 100W port, 1,200W AC input for a one-hour full charge, 500W solar input and a quoted noise level under 29dB. It weighs 12kg. For a single-person home office running a laptop and a monitor, its continuous rating leaves comfortable headroom over the roughly 100W those devices draw.

For the heavy band, the OUKITEL P2001 Plus offers 2,048Wh with a 2,400W continuous inverter, 4,800W surge, four AC outlets, 1,800W AC input for 80% charge in an hour, 500W solar input and a quoted noise level under 50dB, in a 22kg package described as splash and dust resistant. Its 4,000+ cycle LiFePO4 pack and app control over WiFi and Bluetooth are the details that matter for a unit you will leave in place for years.

Quick Decision Flowchart: Matching Your Devices to the Right Station

Work down this list until a row matches your situation, then stop. Later rows assume earlier ones do not apply.

If this describes you Then Check first
Outages in your area are rare and under 15 minutes Skip the battery; buy a good USB-C charger and a cable tray Whether your router is on a UPS already
You only need to protect a desktop tower from reboots Buy a small dedicated UPS Desktop power supply hold-up time and UPS runtime at your load
You run a laptop and need 4–8 hours of cover 500Wh class station That at least one USB-C port delivers 100W, plus one AC outlet
You run a laptop plus monitor plus router for a full day 1,000Wh class station Continuous AC rating above ~300W, and the published noise figure
You run a desktop workstation, or two people share the office 2,000Wh class station Surge rating, floor space, and whether a transfer time is stated at all
Outages in your area routinely last more than a day Station plus enough panel to replace daily consumption Solar input cap and the manufacturer's panel compatibility list
Your workspace is a shed, garage or van with no mains Station plus panel as the primary supply Operating temperature range and daily energy budget
You need 240W USB-C EPR charging for a workstation laptop Use the station's AC outlet and the laptop's own adapter Whether any port supports EPR, and whether your cable is 5A e-marked

Edge Cases: When the Standard Rules Don't Apply

You record audio or take calls all day. Fan noise stops being a footnote. Under 29dB is fine; under 50dB is not, if the unit sits within two metres of a microphone. Push the station into a corridor or behind a door and run a longer cable.

Your office is a cold outbuilding. The 0°C to 40°C operating window rules out an unheated garden room for several months a year. Keep the station indoors and treat the outbuilding as a device location, not a battery location.

You have a medical device in the house. Consumer stations are not medical-grade power. If a device's failure has health consequences, the requirement is a certified UPS with a stated runtime and alarm, not a portable station.

You need more than 2,400W continuous. A kettle, a space heater or a large laser printer will exceed the continuous rating of most units in this class, even where the surge figure looks generous. Surge covers start-up peaks, not sustained draw. Heat-generating appliances belong on the mains.

You plan to travel with it. Weight and portability flip the recommendation entirely. A 22kg floor unit is not a travel companion; a 6kg unit with a carry handle is. If the station has to do double duty between desk and campsite, size down and accept shorter runtime.

Your workspace loses power at night. A small built-in light becomes more useful than it sounds — the P800 includes a 3W LED, which is enough to find a torch and a fuse box without hunting for a phone.

Conclusion: A Decision Matrix You Can Actually Use

The single rule that resolves most of this: buy the smallest station whose usable capacity covers one full working day at your measured load, then spend the difference on a fast recharge path rather than more watt-hours. Capacity you never cycle is capacity you paid for and will replace anyway.

Your situation Recommended class Verify before paying
Laptop only, short outages, occasional travel 500Wh class, e.g. OUKITEL P800 One PD 100W port; 6kg weight; 200W solar ceiling
Laptop, monitor, router, full working day 1,000Wh class, e.g. OUKITEL P1000 PLUS Under 29dB noise; 1,200W AC input; four AC outlets
Desktop workstation or shared office 2,000Wh class, e.g. OUKITEL P2001 Plus 2,400W continuous; floor space for 22kg; whether a transfer time is quoted
Multi-day outages Any of the above plus 300–400W of panel Solar input cap and the published compatibility list

Two honest trade-offs to hold in mind. First, every euro spent on stored energy is a euro not spent on a faster charger, a better monitor or a second screen — so only pay for outage cover you will genuinely use. Second, the solar route buys independence at the cost of a second device, a placement problem and a harvest that is realistically 60–80% of what the panel says. Neither trade-off is wrong; both should be made deliberately.

If you are still at the research stage, measure your desk's real consumption for a week first. That single number turns this entire market into a shortlist of two or three units.

Frequently Asked Questions

Can a portable power station run my desktop computer and monitor?

Yes, if the continuous AC rating comfortably exceeds the combined draw — a typical desktop tower plus a 24-inch monitor sits around 230W, which is well inside an 800W inverter. Runtime is the limiting factor rather than power: roughly 1.9 hours from a 512Wh pack, 3.8 hours from 1,024Wh and 7.6 hours from 2,048Wh once conversion losses are allowed for. Check the transfer time as well, because a desktop power supply with a short hold-up time may reboot during the switchover even if the runtime is ample.

How many watts do I need to charge a laptop and phone at the same time?

On the DC side, a 65W laptop plus a phone charging at 10–20W comes to under 100W, which is why a single 100W USB-C PD port alongside a second PD or USB-A port is usually enough for a laptop-plus-phone pairing. What matters is port allocation rather than total wattage: if the laptop is limited to an 18W port, it will lose charge under load no matter how large the battery is.

Is a solar panel worth it for charging a home office station?

It is worth it in two specific cases: outages that routinely exceed a single working day, and workspaces with no mains supply at all. Size the panel by dividing your daily watt-hours by usable peak-sun hours, then dividing again by about 0.7, because real harvest commonly lands at 60–80% of nameplate. If you have no unshaded outdoor position and outages last hours rather than days, the money is better spent on battery capacity.

What's the difference between a charging station and a UPS?

A UPS is mains-tethered and sized in minutes, its job being to hold equipment up long enough for a clean shutdown or a short bridging event. A portable power station is sized in hours, is movable, and is designed to keep devices running rather than to close them down. Many stations offer an EPS mode with a quoted switchover time, but a dedicated UPS remains the safer choice where an interruption itself causes the damage.

Do I need pure sine wave for my laptop and phone chargers?

For laptops, phones and routers, the device's own power supply rectifies the AC to DC anyway, so waveform quality matters less than people expect. It matters much more for mains motors, audio equipment and some active-PFC power supplies, which can buzz or run hot on a modified sine wave. All three stations discussed here specify pure sine wave inverters, which removes the question entirely if you ever add a fan, a printer or a hi-fi to the desk.

How long can a battery-powered charging station power my home office during an outage?

Take the rated capacity, subtract roughly 15% for conversion and usable-energy losses, then divide by your desk's continuous load in watts. A 97W desk gets about 9 hours from 1,024Wh, while a stripped-back 67W setup gets about 6.5 hours from 512Wh. Measure the real load with a plug-in energy meter rather than adding up charger ratings — those ratings are ceilings, and the gap between the two figures is often close to half.

This article was written using up-to-date sources as of November 2026. Details may change over time — verify current specifics before relying on them.